  1. Cordis CPC Electronic Pressure Controller Troubleshooting Guide

    ... ring at a high frequency for a short period of time when command signals are varied. - Lower the proportional value until the ... It will also become less sensitive to changes in command, and when exhausting to 0% of command, may close the exhaust valve ...

  2. New! Cordis Electronic Flow Controller

    ... and the Clippard EVP or DVP proportional valve. As command is increased, the comparative circuit opens the valve to allow flow to ... sensor detects a value higher or lower than the setpoint command, the proportional valve will modulate more or less output to maintain a ...

  3. Coming Soon! High Volume Cordis Pressure Controller

    ... an onboard microcontroller, analog and digital Command, ±0.25% accuracy, ~5 to 10 mV resolution—now in a new unit that ... Signal/Command   Electrical : 0 to 10 ...

  4. Cordis Pressure Controls Selection Guide

    ... Signal / Command 0 to 10 VDC or Serial ...

  5. How to Plumb Clippard's Cordis Pressure Controller for Vacuum

    ... a 0 to -15 psi or 29” Hg output calibration to a 0-10 VDC command signal, a 10v command will equal full vacuum. The exhaust proportional valve becomes the ...

  6. Cordis Flow Controller FAQ

    ... can be commanded by using voltage, serial or current command. Are there other plumbing options available? A: The Cordis is ... in the field? A: Yes. Refer to the Operations Manual for command sets needed to accomplish this. Can Cordis be calibrated 0 to 5.00 ...

  7. Digital vs. Analog Control in Proportional Applications

    ... to electromagnetic noise. They also facilitate a much richer command set and feedback on process status information. However, digital ... power output to the valves in response to a change in command or operating conditions. Generally speaking, an analog controller will ...

  8. Pressure Control vs. Flow Control

    ... providing feedback to an analog or digital circuit board. A command signal generator (usually a PLC) is used to supply the EPR with a command setpoint. For example, a 0-10 VDC signal (many options exist) directly ...

  9. Pressure Sensor Ranges for the Cordis CPC Series Electronic Pressure Regulators

    ... about it bleeding expensive gases out to atmosphere. Our command capabilities are 0 to 10 VDC, 4-20 mA, and 3.3 volt serial. 3.3 volt ... pressure sensors to choose from, you can now configure your command and output to be as specific as possible in your application ...

  10. Cordis CPC Electronic Pressure Controls FAQ

    ... be made in the field? A: Yes. Refer to the IOM for command sets required to accomplish this. Can Cordis be calibrated 0 to ... of the Cordis unit? A: The Cordis can respond to command signal changes of 5 mV.       Tags:  ...