  1. How to Select Electronic Directional Control Valves

    ... to the room. Clippard's ET-2-12 with threads on the inlet port and threads on the outlet port could be referred to as fully ported ... is a 2/2 valve that is not sensitive to which port is the inlet or the outlet. In Europe this is referred to as a bi-stable valve. ...

  2. Using Multi-Channel Gradient Valves to Mix Corrosive Media

    ... harsh cleaning agents, or other aggressive media. Multiple inlet flow paths are connected to a single outlet flow path, with each inlet having its own embedded isolation valve. Each NIV series isolation valve ...

  3. Electronic Valve Actuation Types Explained

    ... to the room. Clippard's ET-2-12 with threads on the inlet port and threads on the outlet port could be referred to as fully ported ... is a 2/2 valve that is not sensitive to which port is the inlet or the outlet. In Europe this is referred to as a bi-stable valve. ...

  4. The Importance of Zero Dead Volume Fittings

    ... dead volume by ensuring the outlet seals right against the inlet that takes the medium out of the immediate system (or vice versa). These ... 2, above). Notice there is no gap between the tubing and the inlet’s surface where it must seal and that the tubing is flush against the ...

  5. Gas Mass Flow Controllers - An Overview of Technologies

    ... common components (as shown in the figure to the right)—an inlet port, an outlet port, a mass flow sensor, a proportional control valve, ... and capable of higher industrial-type flow ranges and inlet pressures. Due to the resistive temperature sensing involved in this ...

  6. Clippard Maximatic® Air Pilot Valves Selection Chart

    ... Air Pilot Valves Series No. Inlet Outlet Exhaust Function Cv ... Air Pilot Valves Series No. Inlet Outlet Exhaust Function Cv ...

  7. MME Electronic Valve Installation & Operating Instructions

    ... Connecting the MME-3xxx- 3-way valve inlet and outlet as shown in the diagram:     Connecting the MME-4xxx- 4-way valve inlet and outlet as shown in the diagram:   ...

  8. An Alternative to a 2-Way, Normally-Open Valve

    ... port—which is commonly referred to as the exhaust—as the inlet, and the normal outlet as the outlet, and blocking the typical inlet, I now have achieved the 2-way, normally-open function. I hope this ...

  9. Stability vs. Fill-Time in Proportional Control Applications

    ... such as temperature, downstream volume, line restrictions, inlet pressure, and PID settings. Each of these conditions also contributes to ... an increase in downstream demand, sudden change of inlet pressure, or significant temperature changes. However, an appropriately ...

  10. Pressure Control vs. Flow Control

    ... Reference - Force that determines when the inlet flow equals the outlet flow to provide a constant outlet pressure, often ... pressure regulator (EPR) is 2 valves and a sensor. One inlet valve, one exhaust valve and an internal pressure transducer actively ...