| **Note | Please consult factory for current pricing |
|---|---|
| 2D File | 2D File |
| Accessories | 3.3 VDC Serial Cable: CPCH-C2, Actuation Cable, 8-Pin, 6': CPCH-C1, Mounting Bracket: CPCH-B2 |
| Accuracy | ≤2% of Full Scale |
| Applications | Applications Form |
| Calibrated Flow Range | 0 to 6 l/min |
| Current Draw | ≤250 mA max. |
| Data Sheet | Data Sheet |
| Filtration | 40 micron (recommended) |
| Flow Range | Minimum: 0 to 15 sccm, Maximum: 0 to 6 l/min |
| Function | Normally-Closed Proportional |
| Hysteresis | ≤1% |
| Linearity | ≤1% |
| Material, Manifold | Anodized Aluminum |
| Material, Sensor | Polyamide |
| Max. Inlet | 60 psig (4 bar) |
| Medium | Clean, Dry, Non-Corrosive Gases |
| Mounting Attitude | Any |
| Operating Instructions | Operating Instructions |
| Operating Temperature Range | Proportional Valve: 32° to 120°F (0 to 49°C) |
| Porting | G1/8 |
| Pressure Drop | ≤14" H2O |
| Product Line Brochure | Cordis Electronic Controls |
| Protection Rating | IP65 |
| Protection Rating | IP65 |
| Regulated Supply | No Regulator |
| Repeatability | ≤1% |
| Resolution | ≤25 mV |
| Response Time | <50 ms (application dependent) |
| Signal/Command | 0.2 to 10 VDC |
| Supply Pressure | 51 to 60 psig |
| Turndown Ratio | 50:1 |
| Type | Housed Unit |
| Voltage | 15 to 24 VDC |
| Warm-Up Period | <1 Minute |
| Weight (lbs.) | 0.4000 |