Cordis Electronic Flow Controller

Configure CFC

The Cordis Flow Controller utilizes an extremely fast-reacting mems technology sensor upstream from Clippard's proportional valve. Unlike other mass flow controllers, the Cordis flow controller requires less than one minute warm-up, features a pressure drop ≤14" H2O, and includes flow ranges as low as 0 to 30 sccm. Standard control options include 0.2 to 10 VDC, 4.32 to 20 mA, and 3.3 VDC Serial. IP65 housing available for light industrial applications.
(Please select a valid configuration)

  • 50:1 turndown ratio
  • Compact size and weight
  • ≤14" H2O pressure drop
  • <1 minute warm-up
  • Multiple low flow ranges
  • <50 ms response time
  • ≤25 mV resolution
  • Optional integrated regulator

  • 2D File2D File
    Accessories3.3 VDC Serial Cable: CPCH-C2, Power Cord, 6': CPCH-CA6, Actuation Cable, 8-Pin, 6': CPCH-C1
    Accuracy≤2% of Full Scale
    ApplicationsApplications Form
    Current Draw≤250 mA max.
    Data SheetData Sheet
    Flow RateMinimum: 0 to 15 sccm, Maximum: 0 to 6 l/min
    FunctionNormally-Closed Proportional
    Hysteresis≤1%
    Linearity≤1%
    Manifold MaterialAnodized Aluminum
    Material, SensorPolyamide
    Max. Inlet60 psig (4 bar)
    MediumClean, dry, non-corrosive gases
    Operating InstructionsOperating Instructions
    Operating Temperature RangeProportional Valve: 32° to 120°F (0 to 49°C)
    Porting1/8" NPT
    Pressure Drop≤14" H2O
    Regulated SupplyNo Regulator
    Repeatability≤1%
    Resolution≤25 mV
    Response Time<50 ms (application dependent)
    Signal/Command0.2 to 10 VDC
    Supply Pressure5 to 10 psig
    Turndown Ratio50:1
    TypeCard Unit
    Voltage15 to 24 VDC
    Warm-Up Period<1 Minute
    Weight0.4000